EasyManua.ls Logo

Sun Oracle Sun Server X4-2 - Page 156

Sun Oracle Sun Server X4-2
276 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
142 Sun Server X4-2 Service Manual May 2014
b. Install the HDDs 4-7 cable connector into the top disk backplane [2].
c. Plug the HDDs 4-7 cable connector into the connector on the right side of the
HBA card (the connector that is closest to the power supplies) [3].
5. Install the PCIe riser with the internal HBA card into PCIe slot 3.
See “Install a PCIe Riser Into PCIe Slots 3 and 4” on page 82.
6. Install all of the server fan modules.
See “Install a Fan Module” on page 54.
7. Return the server to operation.
a. Install the server top cover.
See “Install the Server Top Cover” on page 145.
b. Close the server fan door.
c. Return the server to the normal rack position.
See “Return the Server to the Normal Rack Position” on page 148.
d. Reconnect the data cables to the server and reconnect the power cords to the
server power supplies.
See “Reconnect Data Cables and Power Cords” on page 149.
e. Power on the server.
See “Power On the Server” on page 150.
Verify that the Power/OK status indicator is steady on.
Related Information
“Remove Storage Drive SAS Cables” on page 139

Table of Contents

Related product manuals