242 Sun Server X4-2 Service Manual • May 2014
Related Information
■ “System Chassis Components” on page 229
■ “Cooling Unit Components” on page 231
■ “Disk Backplane Components” on page 232
■ “Memory Device Components” on page 232
■ “Power Unit Components” on page 233
■ “Processor Components” on page 235
■ “System Board Components” on page 235
■ “Hard Disk Drive Components” on page 238
Hard Disk Drive Events
The following table lists hard disk drive events.
SNMP Message: sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A temperature sensor has reported
that its value has gone below an upper fatal threshold setting or above a lower
fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
/SYS/T_AMB
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS0
/SYS/MB/T_IN_PS1
SNMP Message: sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Message: Upper fatal threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its
value has gone above an upper fatal threshold setting or below a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS0
/SYS/MB/T_IN_PS1
SNMP Message: sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Message: Upper fatal threshold no longer exceeded
Severity and Description: Informational; A temperature sensor has reported
that its value has gone below an upper fatal threshold setting or above a lower
fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an
upper or lower threshold.
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS0
/SYS/MB/T_IN_PS1
Messages and Descriptions Sensor Name