250 Sun Server X4-2 Service Manual • May 2014
SNMP Message: sunHwTrapComponentFaultCleared
Oracle ILOM Message: event fault.memory.intel.dimm.ddr3u-unsupported
Severity and Description: Informational; A component fault has been cleared.
This generic ’component’ trap is generated when the SNMP agent does not
recognize the component type.
/SYS/MB
SNMP Message: sunHwTrapComponentFault
Oracle ILOM Message: event fault.memory.intel.mrc.unknown-errcode
Severity and Description: Major; A component is suspected of causing a fault.
This generic ‘component’ trap is generated when the SNMP agent does not
recognize the component type.
/SYS/MB
SNMP Message: sunHwTrapComponentFaultCleared
Oracle ILOM Message: event fault.memory.intel.mrc.unknown-errcode
Severity and Description: Informational; A component fault has been cleared.
This generic ’component’ trap is generated when the SNMP agent does not
recognize the component type.
/SYS/MB
SNMP Message: sunHwTrapMemoryFault
Oracle ILOM Message: event fault.memory.intel.dimm.udimm-unsupported
Severity and Description: Major; A memory component is suspected of causing
a fault.
/SYS/MB/P/D
SNMP Message: sunHwTrapMemoryFaultCleared
Oracle ILOM Message: event fault.memory.intel.dimm.udimm-unsupported
Severity and Description: Informational; A memory component fault has been
cleared.
/SYS/MB/P/D
SNMP Message: sunHwTrapMemoryFault
Oracle ILOM Message: event fault.memory.intel.dimm.sodimm-unsupported
Severity and Description: Major; A memory component is suspected of causing
a fault.
/SYS/MB/P/D
SNMP Message: sunHwTrapMemoryFaultCleared
Oracle ILOM Message: event fault.memory.intel.dimm.sodimm-unsupported
Severity and Description: Informational; A memory component fault has been
cleared.
/SYS/MB/P/D
SNMP Message: sunHwTrapMemoryFault
Oracle ILOM Message: event fault.memory.intel.dimm.4gb-fused
Severity and Description: Major; A memory component is suspected of causing
a fault.
/SYS/MB/P/D
SNMP Message: sunHwTrapMemoryFaultCleared
Oracle ILOM Message: event fault.memory.intel.dimm.4gb-fused
Severity and Description: Informational; A memory component fault has been
cleared.
/SYS/MB/P/D
Messages and Descriptions Sensor Name