Servicing CRUs That Require Server Power-Off 81
Note If the riser does not have a PCIe card installed in slot 3, then lift the latch to
release the PCIe slot 3 filler panel.
4. To release the riser from the motherboard connector, lift the green-tabbed lease
lever on the PCIe riser to the open position [2].
5. Slide the plastic PCIe card retainer, which is mounted on the side of the chassis,
toward the front of the server to release the card(s) installed in the riser [3].
6. Grasp the riser with both hands and remove it from the server [4].
7. Disconnect the SAS storage drive (HDD) cables from the internal HBA card
installed in PCIe slot 4 [5].
Note If the server has four or fewer storage drives, the SAS cable for HDDs 0-3
will be the only one installed.
8. Place the riser on an antistatic mat.