SVAN 971 User Manual
91
Detector
Type of integration of RMS based results for
1/1 Octave and 1/3 Octave analysis: Linear, Fast or
Slow.
Manual
11.2.2
Pause
Automatic pause(s) in the Dosimeter mode, that can
be programmed based on absolute time.
Manual
12.2
Exposure Time
Total time during working day in which the worker is
exposed to the noise. This time is considered for the
LEPd result calculation.
Manual
12.4
Appendix D
Criterion Level
Steady noise level permitted for a full eight-hour
work shift.
Manual
12.3
Threshold
Level
Noise level limit below which the dosimeter does not
accumulate noise dose data.
Manual
12.3
Exchange
Rate
Amount by which the permitted sound level may
increase if the exposure time is halved.
Manual
12.3
ULT Threshold
Level
Threshold level for calculation of ULT results.
Manual
12.3
PTC Threshold
Level
Threshold level for calculation of PTC results.
Manual
12.3

Table of Contents