EasyManua.ls Logo

Systec DB-45 - Relay Board for Motor Control; Motor Control Board for Radial Fan; Fuses on the Back of the Device

Default Icon
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V/D
S
ERIES
E
LECTRICAL ASSEMBLIES
Revision: 2.1 4-23
4.2.5 Relay board for motor control
3
1
2
Fig. 23: Relay board for motor control on the D-23
1 JP3 Gear motor
2 JP1 Power supply
3 JP2 Digital input for motor control
4.2.6 Motor control board for radial fan
See chapter 4.1.6 oben.
4.2.7 Fuses on the back of the device
The following safety elements and fuses (see chapter 2.2 above) are
located on the back of the device:
Safety temperature limiter (STL)
The safety temperature limiter monitors the heating element and triggers if
the temperature exceeds 170 °C. The heater contactor K1 switches off
and cuts the power to the solid state relays (SSR).
Rose-D
Board
JP6
N
L
Res.High elec.(E6)
HE AT ER
ELEMEN T
2900 W
PANL1002-V2
Rose-A
Board
1
2
3
4
5
6
Chamb.high Elec.(E3)
15VDC
4-20mA
POW5
POW4
POW3
POW1
POW2
PB
PA
PA
VCC
PB
GND
WATERPUMP
PULL SOLENOID
VAC.PUMP
VCC
GND
AC1
L
GND
N
JP1
1
2
3
4
JP18
1
2
3
Y12
VAC.BREAK.
12
JP1
JP7
1
2
JP9
JP3
1
2
3
PULL S olenoid D oor open Y27
12
STEAM CH.
JP5
1
2
3
4
5
6
7
FLOW SW.VAC.
12
JP4
1
2
3
4
5
6
Y16
FASTEXH.TOP.
12
12
JP11
1
2
JP15
1
2
3
4
5
6
7
JP5
1
2
3
MainSwitch
JP2
1
2
3
FLOW SW.WAT.
12
JP7
HEADER 3
1
2
3
JP6
1
2
3
4
5
DOOR LOCKED
12
JP12
1
2
5
6
7
8
JP13
1
2
3
4
5
6
7
Y7
FASTEXH.BOT.
12
H2
JP10
1
2
3
4
5
6
7
8
9
10
JP17
1
2
3
4
5
6
JP12
JP8
1
2
3
4
5
JP14
JP13
1
2
3
JP2
JP14
HEADER 2
1
2
JP2
1
2
3
4
JP16
1
2
3
4
5
6
JP9
1
2
3
4
DOOR CLOSED
12
DOOR LOCK
MOTOR 12 DC
1
2
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
4
3
1
2
DOOR UNLOCKED
1
2
1
2
3
12
FAN
(N24 VAC)
(N24 VAC)
AC1 (24 VAC)
AC2
N
N
GND
13 VDC
5 VDC
GND
5 VDC
13 VDC
GND
5 VDC
Main Filter
5V
DATA
5V
GND
GND
5V
DATA
CHAMBER
PRESS
+
-
Huba Control
1
2
3
13 VDC
GND
5 VDC
OUT
JP2
1
2
JP3
JP1
1
2
Rel-Mot Board
JP16
Fuse 5x20 - 1,5A
Fuse 5x20 - 1,5A
Fuse 5x20 - 3,15A
Fuse
5x20 - 3
,15A
Rose-
P Board
F1 F2
F3
F4
“N”
Terminal
Cut off (STB)
12
Y2
H1
(AC1)
(AC4)
5V
GND
F 1 - Free (3,15A)
F 2 - Vacuumpump fuse (3,15A)
F 3 - Water pump fuse (1,5A)
F 4 - PULL Solenoide fuse (1,5A)
F 5 - Primary fuse (800mA)
F 6 - Secondary fuse (5A)
F 7 -
F 8 -
F 9 -
F11- Resettable motor control fuse (3,5A)
Systec DX23
A3
Size:
Date: 28.01.2010
Drawing No:
Drawing name:
Blatt:
1 of 1
Wiring diagram
Systec DX23
F10 -
Heating element overview
DX23 = 2900W (230V)
24VAC-1
24VAC-2
115VAC
115VAC
12VAC
Toroidaltransformer
(230V to 24V)
12VAC
F6
12VAC
F5
JP15
1
2
24
VAC
5 VDC
GND
PRINTER
DATA
MODUL
CN2
1
2
3
4
CN5
1
2
3
4
1
2
3
4
5
6
7
8
9
10
5V
GND
GND
5V
RXD
TXD
DTR
GND
CIRC. PUMP
A2
1
K1
2
A1
RADIAL
VENTILATOR
MOTHERBOARD
24 VAC
M
-
Radial Fan
24V DC
+
X 1.9
X 1.8
X 1.7
X 1.6
X 1.5
X 1.4
X 1.3
X 1.2
X 1.1
! Modified Version !
Ground isn’t connected
F11
VACUUM
12
Y3
WATER COIL
AIRCOOLING
M9
OPTIONAL
(AC3)
VAC PUMP M2
1 2
VAC.WATER
ValveY15
Gen.High elec.(E1)
Gen.Low elec.(E2)
Chamber Temp
RED
WHITE
WHITE
Cond. Temp
WHITE
RED
WHITE
PT100 Temp2
WHITE
RED
WHITE
MPX5700
1
2
3
GEN PRESS
GND
VCC
Y4
COOLING DRAIN
12
Y11
FLUSH COIL
12
Y5
COMP.AIR CH.
12
Y9
12
CONDENCE
Y1
STEAMCOIL.
12
1000?
1
2
Waterpump
M1
M8
M4
Generator
PRESS
RED
WHITE
WHITE
PT-100
PT-100
PT-100
Drain Temp
M
(AC5)
12
Y17a
Water to Res.
1
2
3
4
Elec. aquastop (E5)
Elec. plate(E7)
Aquastopconnector
FLOA T SWITCH RES.
US B
Rose-Com
Board
SD
Card
1
2
3
4
5
P2
JP1
1
2
3
4
5
DB9
5
9
4
8
3
7
2
6
1
6
7
GND
GND
5V
RSO
RSI
GND
RSI
RSO
GND
RSI
RSO
RSI
RSO
GND
GND
5V
JP3
Fig. 24: Fuse block: Position in the circuit diagram

Table of Contents