194 Alarms
CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686) ID: um_t2gateway
Table G.3.d Alarms
Alarm ID Text Def. severity Details
507 Auto switching disabled Warning
Description: Enabled when auto switching is turned off.
Type: Relay Switch (Type ID = 19)
Clear event: Yes
Subid2: Relay switch controller ID
508 Auto switch performed Filtered
Description: Automatic switch is performed. This alarm will stay on until it is manually
confirmed by the operator (see chapter on switch config).
Type: Relay Switch (Type ID = 19)
Clear event: Yes
Subid2: Relay switch controller ID
517 Alarm log cleared Notification
Description: Alarm log was cleared, user in details
Type: System (Type ID = 13)
Clear event: No
518 System is starting up Critical
Description: This alarm is set when the system is starting. Once booted correctly, the
alarm is cleared.
Type: System (Type ID = 13)
Clear event: Yes
519 Forced reset initiated Notification
Description: A reset of the device was forced by the operator.
Type: System (Type ID = 13)
Clear event: No
520 SW loading in progress Notification
Description: Loading of an embedded SW image is in progress
Type: System (Type ID = 13)
Clear event: Yes
521 New SW pending Notification
Description: A SW image has been successfully loaded, but manual reboot is needed for
SW to be activated.
Type: System (Type ID = 13)
Clear event: Yes
524 Simultaneous users Notification
Description: Multiple users with administrator or operator access level are logged in.
Type: System (Type ID = 13)
Clear event: Yes
526 Action performed Notification
Description: Action performed by user. Used to log generic important events, see details
field on each alarm event for additional information.
Type: System (Type ID = 13)
Clear event: No
527 New SW license pending Notification
Description: New SW licenses have been loaded but requires a re-boot to be activated.
Type: System (Type ID = 13)
Clear event: Yes
528 New SW license installed Notification
Description: New SW licenses have been loaded and installed without requiring reboot.
Type: System (Type ID = 13)
Clear event: No
529 Timesync error Major
Description: Not able to synchronize internal time to external time references.
Type: System (Type ID = 13)
Clear event: Yes