Alarms 193
ID: um_t2gateway CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686)
Table G.3.c Alarms
Alarm ID Text Def. severity Details
169 Virtual alarm relay activated Notification
Description: A virtual alarm relay has been activated.
Type: System (Type ID = 13)
Clear event: Yes
Subid3: Relay ID
200 No GPS 1PPS ref. signal Critical
Description: The 1PPS reference signal is lost (The regulator has however not lost
synchronization).
Type: System (Type ID = 13)
Clear event: Yes
201 Lost GPS 1PPS sync. Critical
Description: The clock synchronization mechanism has been resynchronized due to too
large phase error.
Type: System (Type ID = 13)
Clear event: Yes
210 Emergency switch active Notification
Description: A user has activated the remote emergency switch.
Type: System (Type ID = 13)
Clear event: Yes
211 Emergency switch unreachable Warning
Description: The device is not able to communicate with the remote emergency switch.
Type: System (Type ID = 13)
Clear event: Yes
212 Emergency switch rule config error Warning
Description: An error has been detected in the configuration of the emergency switch.
Type: System (Type ID = 13)
Clear event: Yes
501 User logged in Notification
Description: This event is generated when a user logs on to the system.
Type: System (Type ID = 13)
Clear event: No
502 User logged out Notification
Description: This event is generated when a user logs out from the system.
Type: System (Type ID = 13)
Clear event: No
503 System started Notification
Description: The system has booted.
Type: System (Type ID = 13)
Clear event: No
504 Switch done Notification
Description: The input relay has switched position.
Type: Relay Switch (Type ID = 19)
Clear event: No
Subid2: Relay switch controller ID
505 Config changed Notification
Description: A modification has been made to the configuration of the device.
Type: System (Type ID = 13)
Clear event: No
506 Unable to switch Warning
Description: The relay controller is unable to switch because the spare input is not
sufficiently good.
Type: Relay Switch (Type ID = 19)
Clear event: Yes
Subid2: Relay switch controller ID