192 Alarms
CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686) ID: um_t2gateway
Table G.3.b Alarms
Alarm ID
Text Def. severity Details
154 Data lost Critical
Description: The data stream received for a channel is incomplete, and if running FEC, the
FEC engine is not able to recover all the lost frames.
Type: IP Input (Type ID = 23)
Clear event: Yes
Subid2: IP input channel identifier
155 No lock Critical
Description: The incoming packet stream is absent or incompatible with the expected
format.
Type: IP Input (Type ID = 23)
Clear event: Yes
Subid2: IP input channel identifier
157 Too low latency for FEC Warning
Description: The preferred latency is set lower than the latency required to fully utilize the
current FEC.
Type: IP Input (Type ID = 23)
Clear event: Yes
Subid2: IP input channel identifier
160 SNTP server unreachable Warning
Description: The unit is not receiving answers from the SNTP server.
Type: System (Type ID = 13)
Clear event: Yes
161 Too high temperature Warning
Description: Internal temperature of unit is too high.
Type: System (Type ID = 13)
Clear event: Yes
162 Defective fan Warning
Description: One or more fans are not spinning.
Type: System (Type ID = 13)
Clear event: Yes
163 Time reference unreachable Warning
Description: No selected timesources are OK.
Type: System (Type ID = 13)
Clear event: Yes
164 Illegal board configuration detected Critical
Description: A board configuration that is incompatible with this product has been
detected.
Type: System (Type ID = 13)
Clear event: Yes
165 Time source not OK Notification
Description: One or more time sources are not OK.
Type: System (Type ID = 13)
Clear event: Yes
166 Time source switch Notification
Description: Device started using a new time source.
Type: System (Type ID = 13)
Clear event: No
167 Time adjusted Notification
Description: The real time clock of the device was adjusted significantly.
Type: System (Type ID = 13)
Clear event: No
168 Power failed Warning
Description: One or more power supplies have failed, or are out of regulation.
Type: System (Type ID = 13)
Clear event: Yes
Subid3: Power supply ID

Table of Contents