Glossary
Glossary- 4
TDS5000 Series User Manual
Equivalent time samplin g (ET)
A sampling mode in which the oscilloscope acquires signals over many
repetitions of the event. These oscilloscopes use a type of equivalent time
sampling called random equivalent time sampling, which uses an internal
clock that runs asynchronously with respect to the input signal and the signal
trigger. The oscilloscope takes samples continuously, independent of the
trigger position, and displays them based on the time difference between the
sample and the trigger. Although the samples are taken sequentially in time,
they are random with respect to the trigger.
Fall time
A measurement of the time it takes for the trailing edge of a pulse to fall
from a HighRef value (typically 90%) to a LowRef value (typically 10%) of
its amplitude.
Frequency
A timing measurement that is the reciprocal of the period. Measured in Hertz
(Hz) where 1 Hz = 1 cycle per second.
Gated measurements
A feature that lets you limit automated measurements to a specified portion
of the waveform. You define the area of interest using the vertical cursors.
Glitch positive trigger
Triggering occurs if the oscilloscope detects positive spike widths less than
the specified glitch time.
Glitch negative trigger
Triggering occurs if the oscilloscope detects negative spike widths less than
the specified glitch time.
Glitch either trigger
Triggering occurs if the oscilloscope detects either positive or negative spike
widths less than the specified glitch time.
GPIB (General Purpose Interface Bus)
An interconnection bus and protocol that allows you to connect multiple
instruments in a network under the control of a controller. Also known as
IEEE 488 bus. It transfers data with eight parallel data lines, five control
lines, and three handshake lines.
Graticule
A grid on the display screen that creates the horizontal and vertical axes. You
can use it to visually measure waveform parameters.
Ground (GND) coupling
Coupling option that disconnects the input signal from the vertical system.
Hard copy
An electronic copy of the display in a format useable by a printer or plotter.

Table of Contents

Other manuals for Tektronix TDS5052

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5052 and is the answer not in the manual?

Tektronix TDS5052 Specifications

General IconGeneral
BrandTektronix
ModelTDS5052
CategoryTest Equipment
LanguageEnglish

Related product manuals