Parts Description
Related components
• CAPIOX centrifugal pump
• CAPIOX EBS Circuit with X coating
• CAPIOX Luer Thermistor
• CDI System 500
• Pressure sensor (complied with ANSI/AAMI BP22:1994) * Limited to those that can be connected to connectors.
18
Do not use this system with any equipment other than the dedicated medical equipment. If equipment other than the
dedicated medical equipment is used, this may result in decreased performance.
Do not attach the ABD/Flow Sensor and the Fast Clamp to any tube other than the dedicated tube (internal diameter:
9.5 mm (3/8 inches)). If a tube other than the dedicated tube is used, this may result in decreased performance.
Do not use any cable other than the included AC power cable. Otherwise an electric shock or short circuit may occur
resulting in failure of this system.
Make sure to use a pressure sensor which conforms to ANSI/AAMI BP22:1994. If a pressure sensor that does not conform
to the aforementioned standard is used, this may result in decreased performance.
Before use, check the instructions for use of the medical supplies and medical equipment that are used in combination.
Use the following dedicated devices for this system. Drive Motor (Catalogue No.: ME
*
SP200M), Hand Crank (Catalogue
No.: XX
*
SP05), ABD/Flow Sensor (Catalogue No.: ME
*
SPFAS01, ME
*
SPFAS02), Temperature Sensor Cable (Catalogue
No.: XX
*
SPCBL011, XX
*
SPCBL012), Pressure Sensor Cable (Catalogue No.: XX
*
SPCBL021), Fast Clamp (Catalogue
No.: ME
*
SPCLP01), CDI Communication Cable (Catalogue No.: XX
*
SPCBL031), Cart (Catalogue No.: XX
*
SPCRT01),
Fast Clamp Attachment (for EBS) (Catalogue No.: XX
*
SPCLP01), Fast Clamp Arm (Catalogue No.: XX
*
SPCLP02). If other
devices are used, this may result in decreased performance. In addition, influence may be given to the emission level of
electromagnetic wave and the tolerance of this system.
Cautions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terumo CAPIOX EBS Circuit with X coating and is the answer not in the manual?

Terumo CAPIOX EBS Circuit with X coating Specifications

General IconGeneral
BrandTerumo
ModelCAPIOX EBS Circuit with X coating
CategoryMedical Equipment
LanguageEnglish

Related product manuals