CAPIOX
®
Emergency Bypass System
Instructions for use

Table of Contents

Questions and Answers

  • C
    christophermartinezAug 19, 2025
    What to do if Terumo Medical Equipment doesn't switch to battery after AC power loss?
    • K
      Kevin ColemanAug 20, 2025
      If your Terumo Medical Equipment doesn't switch to battery power when the AC power is cut off, the battery may be low. Charge the battery. If charging doesn't solve the problem, the battery may be damaged.
  • M
    mvalentineAug 21, 2025
    What if the AC power lamp doesn't light up on Terumo Medical Equipment?
    • V
      vhawkinsAug 21, 2025
      If the AC power lamp on your Terumo Medical Equipment doesn't light up, ensure the AC power source is properly connected by reconnecting the AC power cable.
  • C
    Christy SteinAug 25, 2025
    How to fix unstable flow display on Terumo Medical Equipment?
    • D
      Daniel HorneAug 25, 2025
      If the flow is displayed as “-.--” and is unstable, it may be due to several reasons: * The ABD/Flow Sensor is not properly connected: Reconnect the ABD/Flow Sensor. * The ABD/Flow Sensor is not properly attached on the tube: Reattach the ABD/Flow Sensor on the tube. * The detection window of the ABD/Flow Sensor is dirty: Remove the ABD/Flow Sensor from the tube to clean, reapply vaseline and reattach on the tube.
  • J
    Jill MillerAug 26, 2025
    Why can't I export history data to USB from Terumo Medical Equipment?
    • C
      Cynthia WardAug 26, 2025
      If the button that exports history data to a USB memory drive does not function, it may be because the Drive Motor is running. Output data to the USB memory drive after stopping the Drive Motor.
  • P
    Patrick WeeksAug 28, 2025
    Why is the temperature display unstable on Terumo Medical Equipment?
    • N
      Nicholas Scott DDSAug 28, 2025
      If the temperature is displayed as “--.-” and is not stable, it could be because: * The Temperature Sensor Cable is not properly connected: Reconnect the Temperature Sensor Cable. * The CAPIOX Luer Thermistor is not properly connected: Reconnect the CAPIOX Luer Thermistor. * The CAPIOX Luer Thermistor has failed: Replace the CAPIOX Luer Thermistor.
  • S
    Samuel GalvanAug 30, 2025
    Why motor speed displayed as '----' on Terumo Medical Equipment?
    • D
      Daniel BurtonAug 30, 2025
      If the motor speed is displayed as “----” and the centrifugal pump does not rotate, the Drive Motor might not be properly connected. Reconnect the Drive Motor.
  • P
    pamelanewmanSep 1, 2025
    Why doesn't the charge lamp light up on my Terumo Medical Equipment?
    • M
      Manuel WoodwardSep 1, 2025
      If the charge lamp does not light up, it might be because the battery is fully charged, meaning it cannot be charged further, and there is no abnormality.
  • W
    William VincentSep 3, 2025
    What if Terumo Medical Equipment battery doesn't reach 100% after charging?
    • S
      Sara LeeSep 3, 2025
      If the battery charge level is less than 100% even after charging is completed, the battery may have deteriorated.
  • R
    Robert LopezSep 5, 2025
    Why doesn't the clamp ready lamp light up on Terumo Medical Equipment?
    • J
      Jennifer MillerSep 5, 2025
      If the Clamp ready lamp does not light up, check the following: * The Fast Clamp is not properly connected: Connect the Fast Clamp. * The fast clamp function is not on: Enable the fast clamp function. * The safety connection which allows the Fast Clamp to operate has not been set: Set the safety connection. * The tube has not been securely set or the lid is not properly closed: Set the tube and close the lid.
  • B
    Brandy BaileySep 8, 2025
    Why can't I clamp from the Fast clamp screen on Terumo Medical Equipment?
    • R
      Rachel SmithSep 8, 2025
      If the Fast Clamp cannot be clamped from the button on the Fast clamp screen, it could be because: * The tube has not been securely set or the lid is not properly closed: Set the tube and close the lid. * The fast clamp function is not on: Enable the fast clamp function. * The Drive Motor is running: Execute the clamp after stopping the Drive Motor.

Summary

Symbols on Packages

Contents and Description of Product

Product Structure

Details the physical layout and components of the CAPIOX EBS.

Warnings and Precautions

Precautions for Operation

Provides critical safety guidelines for operating the CAPIOX EBS system.

Precaution for Storage

Outlines proper storage conditions to maintain device integrity.

Instructions for Use

Set Up Procedure

Step-by-step guide for setting up the CAPIOX EBS system.

Priming Procedure

Detailed steps for priming the CAPIOX EBS circuit before use.

Connection Steps

Instructions for connecting the CAPIOX EBS to the patient circuit.

Initiation of Bypass

Procedure for initiating the bypass function of the CAPIOX EBS.

During Perfusion

Guidelines for operating the CAPIOX EBS during perfusion.

Termination of Bypass

Steps for safely terminating the bypass procedure.

Circuit Replacement

Procedure for replacing the CAPIOX EBS circuit.

Data and Specifications

Technical data and specifications for the CAPIOX EBS.

Purpose, Overview, and Features of the Product

Purpose and Overview

Introduction to the CAPIOX Centrifugal Pump Controller SP-200.

Product Features

Highlights key features of the CAPIOX Centrifugal Pump Controller SP-200.

Parts Description

System Configuration Example

Illustrates the system setup with the controller and connected components.

Controller Component Details

Describes the front, control panel, rear, and bottom views of the controller.

Device Behaviour and LCD Display

Explains coast speed behavior and LCD touch panel displays.

Controller Components and Accessories

Details controller display units, optional accessories, and related components.

Precautions for Safe Use

General Use and System Precautions

Covers broad safety guidelines for system operation and handling.

Component-Specific Precautions

Details safety advice for specific components like the controller and sensors.

Electrical, Environmental, and Interference Precautions

Addresses electrical safety, environmental factors, and electromagnetic interference.

Storage and Cleaning Precautions

Provides guidelines for proper storage and cleaning procedures.

Ambulance Installation Precautions

Specific precautions for installing and using the system in an ambulance.

Operation Procedure

First-Time Use and Touch Panel Operations

Guide for initial system setup and touch panel interaction.

Preparation and System Setup

Steps for preparing the system and attaching the controller to the cart.

Connecting Power and System Components

Instructions for connecting AC power, drive motor, sensors, and cables.

Pre-Circulation Inspections and Start

Details inspections required before circulation and how to start it.

Pump and Component Assembly

Procedures for connecting the centrifugal pump and attaching components.

Sensor Connections and Priming

Steps for connecting temperature/pressure sensors and filling with priming solution.

System Activation and Configuration

Covers powering on the system, confirming setup, auto-priming, and calibration.

Fast Clamp Procedures

Instructions for attaching, using the attachment, and using the arm of the Fast Clamp.

During Circulation and Weaning

Guidelines for operation during circulation and the weaning process.

Turning the Power Off

Procedure for safely shutting down the system.

Cart and Accessory Usage

Cart Assembly and Mobility

Details on assembling the cart, locking casters, and moving the unit.

Attaching External Devices to Cart

Instructions for attaching accessories like gas blenders and oxygen cylinders.

Various Menu Settings: User Setup

Setup Modes Overview

Explains the two setup modes: User and Admin.

Flow and Pressure Alarm Settings

Configuration of flow and pressure alarm thresholds.

Pressure and Temperature Measurement Settings

Setup for pressure and temperature measuring functions and alerts.

Fast Clamp and Air Bubble Detector Settings

Configuration of fast clamp and air bubble detector functions.

Safety Connection and Alarm List

Setting safety responses and reviewing alarm configurations.

BSA, Count Down, and History Functions

Setup for Body Surface Area calculation, timers, and history tracking.

USB Data Export and Log Management

Procedures for exporting data via USB and managing logs.

Various Menu Settings: Admin Setup

Admin Setup Overview and Password Management

Accessing and managing admin setup and passwords.

Admin Configuration Options

Details settings for presets, auto-priming, coast speed, and communication.

Specifications

Controller System Specifications

Technical specifications for the CAPIOX Centrifugal Pump Controller SP-200.

System Functions and Conditions

Details alarms, available functions, and environmental/power conditions.

Dimensions, Weight, and Related Components

Physical dimensions, weight, and list of related components.

For Medical Staff: EMC Information

EMC Compatibility and Emissions Guidance

Guidance on electromagnetic compatibility and emissions.

EMC Immunity Guidance

Guidance on electromagnetic immunity for the system.

Symbol Definitions

Terumo CAPIOX EBS Circuit with X coating Specifications

General IconGeneral
Product NameTerumo CAPIOX EBS Circuit with X coating
CategoryMedical Equipment
ManufacturerTerumo
Coating TypeX coating
UsageExtracorporeal circulation during cardiopulmonary bypass
TypeExtracorporeal Blood Circuit
CompatibilityCompatible with Terumo CAPIOX oxygenators