DK40 Universal Slot PCBs
PEMU DC5 Tie Line Unit
3-22
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
PEMU
DC5 Tie Line Unit
System:
DK40 Expansion KSU
Circuits per PCB:
four DC5 tie line circuits
Interfaces with:
DC5 two wire transmission with E & M signalling.
DC5 four wire transmission with E & M signalling.
Compatible Slot(s):
slots 15 ~ 18
Older Version(s):
PEMU1 (not compatible with DK40)
Each PEMU Interface decreases the maximum system exchange lines by four. (See
Chapter 1 – DK40 Configuration).
Note
For the system to recognise the DTMF tones generated by incoming TIE lines a
DTMF Receiver Unit (K5RCU) must be installed on the DK40 Base KSU.
The Strata DK40 system assigns one station port number to each Tie Line connected. These
station port numbers are only available in order to program certain attributes to the Tie Lines
connected to the PEMU, PACU PCBs, (i.e. Toll Restriction and Least Cost Routing). For a
list of the station port numbers assigned to each PEMU PCB/Tie line circuit see Table 3-6 on
Page 3-19
PEMU controls, indicators, and interface connectors are shown in Figure 3-10 and described
in Table 3-8.
PEMU Installation
1. Determine if the E & M tie lines will be configured for 2- or 4-wire transmission.
2. Set the 2W/4W jumper plugs P103, P203, P303, and P403 to the appropriate positions.
3. Set the FG jumper plug P3 to the “2-3” position.
4. Set all GND/BAT jumper plugs to the “BAT” position for connection to the telephone
network.
5. Insert the PEMU (component side facing right) into the appropriate Expansion KSU
cabinet slot and apply firm, even pressure to ensure proper mating of connectors.
Important!
Each PEMU decreases the maximum system exchange lines by four each.
6. After installing, gently pull the PEMU outward. If the connectors are properly mated, a
slight resistance is felt.