Reserve Power Option
DK40 Installation
Strata DK40 I&M Manual Spring 1999
2-17
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Reserve Power Option
A reserve power source (two customer supplied 12-volt batteries) can be connected to the
DK40 power supply to ensure uninterrupted system operation in the event of a power failure.
A pre-assembled interface cable for installation of the Reserve Power option is available from
Toshiba (PBTC-3M), see Figure 2-12.
The batteries require a well-ventilated location within 3m of the system (the interface cable is
3m long).
Actual Size
PBTC-3M
Battery Cable with
Ring Terminals
and PPSU Connector
(length - 3 metres)
Power Supply
BATT
Two-prong Male
Connector
(pre-assembled)
Black
White
In-line Fuse Holder 10 A
(Fuse Provided)
Black Jumper with
Ring Terminals
(provided)
White
Black
12 VDC
Battery
+
12 VDC
Battery
+
TPSU40
+
Ring Terminals 3/8 In.
16AWG
2164
Figure 2-12 System Power Supply Wiring

Table of Contents