Peripheral Installation
Auto Attendant
6-50
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Alarm Sensor Options
Note
Refer to Figure 6-26 for additional information.
Jumper plug P12 on the PIOU is used to set the alarm sensor to detect an open or closed
condition from the facility alarm system.
➤ To detect an open or closed condition by the jumper plug P12
1. To detect a closed condition, set P12 to the N.O. position.
2. To detect an open condition, set P12 to the N.C. position.
Jumper W3 on the PIOUS is used to set the alarm sensor to detect an open or closed condition
from the facility alarm system
➤ To detect an open or closed condition by soldering the W3 jumper wire
1. To detect a closed condition, solder W3 to the normal open position.
2. To detect an open condition, solder W3 to the normal closed position.
Alarm Sensor Wiring
Refer to Figure 6-26, and connect the facility alarm system relay contacts to the PIOU/
PIOUS PCB.
Auto Attendant
Auto Attendant operates like an automatic station attendant or switchboard operator that
quickly and efficiently distributes calls to stations selected by callers. Incoming calls are
greeted by an external announcement device that offers callers a menu of station locations
PIOU PCB
N.C.
N.O.
P12
Alarm
Sensor
ALMT (36)
ALMR (11)
25-Pair Cable
PIOU Pin Numbers ( )
25-Pair Cable
Facility
Alarm
System
MDF
Alarm
Sensor
Normal Close
Normal Open
ALMT
ALMR
W3
ALM
TB1
Twisted
Pair
PIOUS PCB
MDF
Facility
Alarm
System
1541
Figure 6-26 DK40 Alarm Sensor Block Diagram (PIOU/PIOUS)