Relay Control Options and Door Lock Control
Peripheral Installation
Strata DK40 I&M Manual Spring 1999
6-15
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Door Lock Control with DDCB
In addition to the option interface PCB (PIOU, PIOUS, PEPU), each DDCB can provide one
door lock control.
DK40
provides three door lock controls.
DK40 DDCBs connect only to digital circuits (always circuit 5 on a PDKU) (see
Table 6-1).)
Important!
Each DDCB door lock control reduces the maximum door phone capacity by
one.
Configure Each DDCB for the Door Lock Control Function
1. DK40 : connect PDKU circuit 5 (A/B and PA/PB) to the DDCB HKSU modular jack
(see Figures 6-9 and 6-10).
2. Connect the door lock wire pair to the DDCB modular B-jack (pins 3 and 4).
3. Set SW1 to the DOOR position.
4. Set SW2 to the LOCK position.
5. SW3 inside the DDCB can be set to open or close the door lock relay whenever a door
lock button is pressed: if SW3 is in the “1-2” position, the relay closes when the button
is pressed; if in the “2-3” position, the door lock relay opens when the button is pressed.
Note
SW3 comes from the factory in the “1-2” position.
6. In Program 77-1, set the door lock activation for three or six seconds and enable the
PDKU ports for DDCB connection.
7. In Program 77-2, enable the DDCB B-jack for door lock operation and specify 1 or 5
rings when door button is pressed.
8. In Program 39, assign door lock buttons to stations per the customers record sheet.
9. In Program 79, specify door phone ringing assignments.
10. Check each telephone door lock button from each station: the DDCB modular B-jack
(pins 3 and 4) will momentarily open or close (three or six seconds) when the button is
pressed.
Table 6-1 DDCB DRLK Assignments Guide
DK40 KSU or
PDKU
DDCB
No.
Port No. Program 39 Button Assignments
DK40 Door Lock 1 1 004 (CCT 5) Unlock Door 1 (DRLK 1), Code 72
DK40 Door Lock 2 2
Port 004 (CCT 5) of 1st PDKU
(DK40 Expansion Unit)
Unlock Door 2 (DRLK 2), Code 73
DK40 Door Lock 3 3
Port 004 (CCT 5) of 2nd PDKU
(DK40 Expansion Unit)
Unlock Door 3 (DRLK 3), Code 74