DK40 Installation
Site Requirements
2-2
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Input Power
The system requires an input power source of 220~240 VAC, 50/60 Hz, 13 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire earth. (See
“AC Power and Earthing Requirements” on Page 2-4 for more information..)
This eliminates interference from branch circuit motor noise or the like, and to prevent
accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do
not use an ON/OFF wall switch on this dedicated AC circuit.
For the Strata DK40, a reserve power source (two customer-supplied 12-volt batteries) may
be connected to the system to serve as a power failure backup.
Clearance and Location
The minimum clearance requirements for the Strata DK40 Base and Expansion KSUs are
shown in Figures 2-1 and 2-2. Refer to Page 2-1 for DK40 KSU mounting instructions.
Consider the following conditions when selecting a location for the KSU(s):
The location must be:
◆ Dry and clean
◆ Well ventilated
◆ Well illuminated
◆ Easily accessible
50.5mm
457.0mm
Front View
311mm
Top View
88.5mm
915.0mm
Wall
DK40
Base KSU
2158
50.5mm
50.5mm
50.5mm
Figure 2-1 DK40 Base KSU Clearance
Requirements
457.0mm
Front View
507.5mm
Top View
88.5mm
915mm
Wall
50.5mm
DK40
Base KSU
Expansion
Unit
BaseExpansion
1625
50.5mm
50.5mm
50.5mm
Figure 2-2 DK40 Base KSU and
Expansion KSU Clearance
Requirements