Installation
DK40 ACD Installation
Strata DK40 I&M Manual Spring 1999
7-3
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Digital announcement devices can be connected to DK40 standard telephone ports only;
music sources such as digital Music-on-Hold (MOH) devices, radio tuners, CD players, etc.,
can be connected to standard telephone ports, or to the CTU MOH jack. The wiring diagrams
for connecting announcement/music devices are:
Digital announcers and/or music sources to standard telephone PCB ports: RSTU,
PSTU or KSTU3 – See Chapter 4 DK40 Universal Slot PCB Wiring Diagrams.
Digital announcement devices and music sources can be assigned to any standard
telephone port; they are not restricted to designated Background Music (BGM) source
ports (see Program 14-3 in the Strata DK40 Programming Manual for assignments).
Announcement devices are designed to connect directly to standard telephone ports. Do
not use an isolation transformer to connect digital announcers.
Important!
Most music sources (600 or 8 OHM) are not designed to be connected to
telephone line circuits like the Strata DK40 standard telephone circuits. When
connecting these devices to standard telephone circuits, an isolation
transformer may be required between the music source and the standard
telephone circuit. Figure 6-4 shows how to connect an isolation transformer.
Music source to DK40 MOH input: The MOH source connected to the CTU MOH
jack can be sent to ACD Groups selectively via Program 14-3.
Toshiba
TTY-PC-CABLE
6-pin modular jack9-pin PC serial COM port (DB-9)
1
PC parallel
printer port
ACD/SMIS/Insight DK
Personal
Computer
TTY jack:
PIOU or
PIOUS
MIS RS-232 port
Strata DK40
Sentinel key
(off-white colour, comes with SMIS
software version V1.0 or higher or
Insight DK)
2040
Figure 7-2 SMIS/ACD Wiring Diagram
1
Install PIOU or PIOUS PCBs in the last (highest numbered) slot in the Expansion Cabin
e