EasyManua.ls Logo

Toshiba Strata DK40 - Figure 6-22 SMDR Printout Example Column;Field Definitions

Toshiba Strata DK40
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Peripheral Installation
SMDR Printer/Call Accounting Device Options
6-40
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Figure 6-22 SMDR Printout Example Column/Field Definitions
1522B
Exchange Line Number (001 ~ 012).
*
Indicates a disconnected call.
[PDN] of the Station (1~4 digits)
2
making/answering a call.
"ABAN" represents an unanswered incoming call
"MSS" represents an incoming DISA call
"DISA" represents an incoming call following External Call Forward.
Time of Day (HH:MM; hour and minute the call was released).
Call Duration (HH:MM;SS). If a '
*
' appears in column 79 (see J) then this
time is actual talk time.
Exchange Line Incoming Ring Duration Before Answer (MM:SS). If the call
is outgoing this field will be empty.
Station to which the exchange line was transferred (1~4 digits).
Outgoing Telephone Number (1 ~ 26 digits)
Account Code (4~15 digits)
Outgoing Call answered indication. If the call is unanswered a space will be
inserted.
Incoming call CLI
Sub-Address dialled fo outgoing calls (1 ~ 20 digits)
Sub-Address received on incoming calls (1 ~ 20 digits)
Field Number (1 ~ 3)
Field Number (4)
Field Number (5 ~ 8)
Field Number (10~14)
Field Number (16 ~ 23)
Field Number (25 ~ 29)
Field Number (31 ~ 34)
Field Number (36 ~ 61)
Field Number (63 ~ 77)
Field Number (79 ~ 79)
Field Number (81 ~ 96)
Field Number (98 ~ 117)
Field Number (119 ~ 138
A
B
C
D
E
F
G
H
I
J
K
L
M
General Notes
1
Call Duration (incoming, outgoing, or transfer) must be 1 or 10 seconds (minimum) to generate
a call record printout. It can be set to 1.0 or 10 seconds using Program 60-2.
2
“MSS”: designates a Direct Inward System Access (DISA) or External Call Forward CO call to
a station that is not answered; or, answered after 1 or 10 seconds per Program 60-2. The call will
register as a normal incoming call if answered before the threshold time (1.0 or 10 seconds
depending on Program 60-2). DISA calls always register 05~06 seconds ring before answer
duration time.
3
“MODM”: designates a call to the IMDU, Remote Maintenance Modem.
4
Field column information is provided for SMDR output formatting purposes.
5
DK40 will send a Carriage Return (CR) and Line Feed (LF) ASCII symbol after each line of
data.
6
The call record data is ASCII-formatted, 8 bits; no parity, 1-stop bit.
7
Special dial printout: Tone = “T”, Long pause = “L”, Flash = “F”, Pause = “P”