EasyManua.ls Logo

Toshiba Strata DK40 - Figure 4-7 PEKU Station MDF Cross Connect Record

Toshiba Strata DK40
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DK40 Universal Slot PCB Wiring
Station Wiring Diagrams
4-8
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
1
Indicate if electronic telephone or HDCB (HDCB: Circuit 5, PEKU PCB).
2
Indicate if electronic telephone or HDSS Console number (1~8).
Figure 4-7 PEKU Station MDF Cross Connect Record
MDF Block Number KSU Slot Number
Colour Code Designation
CCT
Number
Port
Number
Intercom
Number
Device/Standard Telephone/
Electronic Telephone Location
W-Bl VA
1
Bl-W VB
W-O DA
O-W DB
W-G VA
2
G-W VB
W-Br DA
Br-W DB
W-S VA
3
S-W VB
R-Bl DA
Bl-R DB
R-O VA
4
O-R VB
R-G DA
G-R DB
R-Br VA
5
See Note 1
Br-R VB
R-S DA
S-R DB
Bk-Bl VA
6
Bl-Bk VB
Bk-O DA
O-Bk DB
Bk-G VA
7
See Note 2
G-Bk VB
Bk-Br DA
Br-Bk DB
Bk-S VA
8
See Note 2
S-Bk VB
Y-Bl DA
Bl-Y DB

Table of Contents