EasyManua.ls Logo

Toshiba Strata DK40 - Flowchart 9-5 DSS Console Faults

Toshiba Strata DK40
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Finding
Fault Isolation Flowcharts
9-12
Strata DK40 I&M Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Flowchart 9-5 DSS Console Faults
START
DSS
console
type?
5-0
END
DDSS
Go to
5-0
Is the correct
PCB slot code entered
in Program 03?
Enter correct PCB slot
code using Program 03;
then turn power OFF
(for 5 seconds) and
then ON.
5-3
Refer to Chapters 2 & 4 and
verify wiring:
Is the
fault
cleared?
Yes
5-4
Go to
5-3
HDSS
No
On PEKU connected
to HDSS, set SW1
to the DSS position.
5-1
No
5-2
Is the
fault
cleared?
For DDSS, circuit 8 of the base
unit or PDKU.
For HDSS, circuit 7 and 8 of
PEKU ).
Correct as necessary.
Correct as necessary.
Is the
fault
cleared?
Yes
5-5
Call your technical
support group.
No
END
END
No
Yes
Yes
1883
Test DSS cable with cable continuity
checks in this chapter.

Table of Contents

Other manuals for Toshiba Strata DK40