Worksheet 1 – System PCB Assignment Guide
DK40 Configuration
Strata DK40 I&M Manual Spring 1999
1-11
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Worksheet 1 – System PCB Assignment Guide
This worksheet helps you configure the system. Use the following table to record the
hardware that comprises the system. Consult the following Configuration tables when you fill
out Table 1-11 below. See Figure 2-11 on Page 2-16 for DK40 universal slot locations.
Configuration Rules
◆ Stratagy DK can be installed in place of PDKU2, PEKU, or PSTU to provide two, four,
six or eight built-in Automated Attendant/Voice Mail circuits. Always install Stratagy
DK in slot 15, 16, or 17; do not install Stratagy DK in slot 18. Program the Stratagy VM
ports as if they were standard telephone ports connected to an external VM device. All
models of Stratagy DK use up eight station ports.
◆ PEKU can be installed in place of PDKU2, PSTU2, or RSTU2 to provide eight-
electronic telephones instead of digital or standard telephones.
◆ K5RCU must be installed when using built-in automated attendant, standard telephone
ports, tie lines, or DISA Lines.
◆ If required, install PIOU and PIOUS in last available slots starting with slot 18.
◆ Speaker OCA can only be installed on digital telephone ports in the DK40 Base KSU
and slots 15 and 16 of the DK40 Expansion KSU (24 maximum).
◆ Each Tie line PCB installed provides four Tie lines (PEMU, PACU), and has station port
range 028~039 assigned to Tie lines 1~12 respectively for programming purposes.
Customer:
Location:
Table 1-11
DK40 PCB Configuration
Base Cabinet Expansion Cabinet
Slot
Number
00 11 12 13 14 15 16 17
18
PCB
Ty p e
None
K5RCU
DKT
None
None None
TCOU
TBSU KSTU3 N/A
Options
None
OCA/
DSS/
RPCI/
None
None None
Loop Start
Exchange
DTMF
ISDN
BRA
SLT N/A