EasyManua.ls Logo

Toshiba Strata DK40 - Figure 6-7 PIOU;PEPU Relay Control Functional Wiring Diagram

Toshiba Strata DK40
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Peripheral Installation
Relay Control Options and Door Lock Control
6-12
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
PIOU 25 PR.
Connectors
PIN NO. Color
PIOU/PEPU PCB
Door
Lock
Control
Page
Amplifier
Select Relay Function
with Program 77-1
Door Lock or External
Page Control
Break
P10
Make
SW4
SP0
600 (Duplex)
P11
Break
Make
Night
Bell
To Music On-Hold
Input on DK KSU
MDF
Connections
All wires should
be jacketed CW1308
0.5mm twisted pairs
Select Relay Function
with Program 77-1:
Night Relay or
MOH Control
32
7
38
13
34
9
R-O
O-R
Bk-Gn
Gn-Bk
R-Br
Br-R
.
.
.
.
.
.
.
.
DE.T
DE. R
SP.T0
SP.R0
NH.T
NH.R
Control
Speaker
Tape
Player
Page or
BGM from
DK KSU
1507
Notes
1. Dotted lines and solid lines differentiate optional connections where
applicable; do not connect both options simultaneously.
2. The BGM source port connected to the system must have the same
EN60950 Classification as the DK40. This port must therefore be of a
SELV (Safe Extra Low Voltage) Classification.
Figure 6-7 PIOU/PEPU Relay Control Functional Wiring Diagram