RPTU Call Monitoring (PRI)
DK40 Universal Slot PCBs
Strata DK40 I&M Manual Spring 1999
3-43
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Figure 3-23 RPTU Performance Monitor Printout
To exit the dump mode
At the >
D
prompt, type
QUIT
, press
Enter
(or
Return
); the >
MODE
prompt
displays.
DK VERSION 1.0
>CODE
OK
>MODE DUMP
D DASS
##DASS ERROR DISPLAY##
FRAME ALIGNMENT ERROR
06/25/00 THU 09:51:06 SLOT NO. 12 CCT NO. 1
CONTROL SLIP
06/25/00 THU 09:50:19 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:26 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:32 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:38 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:44 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:51 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:57 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:51:06 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:51:09 SLOT NO. 12 CCT NO. 1
CLOCK SOURCE LOST
06/25/00 THU 09:50:18 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:50:18 SLOT NO. 12 CCT NO. 1
06/25/00 THU 09:51:04 SLOT NO. 12 CCT NO. 1
TBSU TTY Remote Prog Fault