2.3 Power Supply Troubleshooting 2 Troubleshooting Procedures
TECRA 9100 Maintenance Manual (960-347) 2-7
Procedure 2 Error Code Check
If the power supply microprocessor detects a malfunction, it indicates the error code as
shown below.
The error code begins with the least significant digit.
Error code
Error code Where Error occurs
1*h Adaptor
(AC Adaptor, DS)
AC Adaptor is not connected.
Error code begins with : 0x10
Error code ends with : 0x1F
2*h The 1st battery The 1st Battery is not connected.
Error code begins with : 0x20
Error code ends with : 0x2F
3*h The 2nd Battery The 2nd Battery is not connected.
Error code begins with : 0x30
Error code ends with : 0x3F
4*h S3V output Operating Power ON
5*h C5V output Error code begins with : 0x40
6*h C3V output Error code ends with : 0xDF
7*h PPV output
8*h PGV output
9*h 1R5-E1V output
A*h 1R8-E1V output
B*h BVGAV output
C*h 1R25-E1V output
D*h 2R5-E2V output
E*h
F*h