2 Troubleshooting Procedures 2.10 COMBO Drive Troubleshooting
2-44 TECRA 9100 Maintenance Manual (960-347)
Procedure 2 Connector Check and Replacement Check
The COMBO drive is connected to the system board. The connectors may be disconnected
from the system board or may be damaged. Disassemble the computer following the steps
described in Chapter 4, Replacement Procedures and perform the following checks:
Check 1 Make sure the COMBO drive is firmly connected to the I/O board.
PJ116
I/O Board
COMBO Drive
If the connection is loose, reconnect firmly and repeat Procedure 1. If there is still
an error, go to Check 2.
Check 2 The COMBO drive may be defective or damaged. Replace the drive with a new
one. If there is still an error, go to Check 3.
Check 3 Replace the system board with a new one following the steps in Chapter 4,
Replacement Procedures. If the problem still exists, perform Check 4.