EasyManua.ls Logo

Toshiba TECRA 9100 Series - TFT FL (Model 14.1 SHARP LQ141 F1 LH23); Removing the TFT FL (Model 14.1 SHARP LQ141 F1 LH23)

Toshiba TECRA 9100 Series
428 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.28 FL (Model 14.1 SXGA+ Sharp) 4 Replacement Procedures
TECRA 9100 Maintenance Manual (960-347) 4-109
4.28 TFT FL (Model 14.1 SHARP LQ141F1LH23)
CAUTION: When you replace the fluorescent lamp, wear finger covers or gloves to
avoid contaminating or damaging the LCD panel. Be careful not to let dust or other
foreign matter into the module.
Removing the TFT FL (Model 14.1 SHARP LQ141F1LH23)
To remove the TFT FL (Model 14.1 SHARP LQ141X1LH23), follow the steps below and
refer to figures 4-80 to 4-84.
1. Turn the LCD module upside down.
2. Remove protective cover-S, protective cover-G, aluminum tape and tape securing
the wire applied to the back of the LCD module. Be careful not to damage the TCP
or ICs. (Dispose of the protective covers and tape you removed.)
Tape to secure the wire
Protective cover-G
Protective cover-S
Pins
Aluminum tape
Figure 4-80 Removing the covers and tape

Table of Contents

Related product manuals