EasyManua.ls Logo

TP-Link T1500 Series - Page 812

TP-Link T1500 Series
844 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration Guide 790
Configuring SNMP & RMON Configuration Example
Choose the type as Inform, and set the retry times as 3, and the timeout period as 100
seconds.
Switch_A(config)#snmp-server host 192.168.1.222 162 admin smode v3 slev authPriv
type inform retries 3 timeout 100

Enable Bandwith-control Trap
Switch_A(config)#snmp-server traps bandwidth-control

Configuring RMON
1) Create two Statistics entries to monitor ports 1/0/1 and 1/0/2 respectively. The owner
of the entries is set as monitor, and the status is set as valid.
Switch_A(config)#rmon statistics 1 interface gigabitEthernet 1/0/1 owner monitor
status valid
Switch_A(config)#rmon statistics 2 interface gigabitEthernet 1/0/2 owner monitor
status valid
2) Create two History entries and bind them to ports 1/0/1 and 1/0/2 respectively. Set the
sample interval as 100 seconds, max buckets as 50, and the owner as monitor.
Switch_A(config)#rmon history 1 interface gigabitEthernet 1/0/1 interval 100 owner
monitor buckets 50
Switch_A(config)#rmon history 2 interface gigabitEthernet 1/0/2 interval 100 owner
monitor buckets 50
3) Create two Event entries named admin, which is the SNMP user name. Set entry 1 as
the Notify type and its description as “rising_notify”. Set entry 2 as the Log type and its
description as “falling_log”. Set the owner of them as monitor.
Switch_A(config)#rmon event 1 user admin description rising_notify type notify owner
monitor
Switch_A(config)#rmon event 2 user admin description falling_log type log owner
monitor
4) Create two Alarm entries. For entry 1, set the alarm variable as BPackets, associated
Statistics entry ID as 1 (bound to port 1/0/1), the sample type as Absolute, the rising
threshold as 3000, the associated rising event entry ID as 1 (Notify type), the falling
threshold as 2000, the associated falling event entry ID as 2 (the log type), the alarm
type as all, the interval as 10 seconds, and the owner name as monitor. For entry
2, set the associated statistics entry ID as 2 (bound to port 1/0/2), while all other
configurations are the same as those of entry 1.
Switch_A(config)#rmon alarm 1 stats-index 1 alarm-variable bpkt s-type absolute
rising-threshold 3000 rising-event-index 1 falling-threshold 2000 falling-event-index 2
a-type all interval 10 owner monitor

Table of Contents

Related product manuals