Configuring SNMP & RMON Configuration Example
Configuration Guide  
  793
 Index   Port             Owner         State
 -----     ----------     ---------      -------
 1            Gi1/0/1      monitor       valid
 2            Gi1/0/2      monitor       valid
Verify RMON history configurations:
Switch_A(config)#show rmon history
Index   Port             Interval   Buckets    Owner          State
-----     ---------      --------    ---------      ----------     ---------
1            Gi1/0/1     100           50                 monitor      Enable
2            Gi1/0/2     100           50                 monitor      Enable
Verify RMON event configurations:
Switch_A(config)#show rmon event
Index    User           Description          Type           Owner            State
-----       ------          -----------              --------        ----------       ----------
1             admin         rising-notify        Notify           monitor       Enable
2             admin         falling-log            Log                monitor       Enable
Verify RMON alarm configurations:
Switch_A(config)#show rmon alarm
    Index-State:           1-Enabled
    Statistics index:    1
    Alarm variable:      BPkt
    Sample Type:        Absolute
    RHold-REvent:      3000-1
    FHold-FEvent:       2000-2
    Alarm startup:       All
    Interval:                  10
    Owner:                     monitor