TR-Electronic GmbH 2016, All Rights Reserved Printed in the Federal Republic of Germany
Page 74 of 153 TR-EMO-BA-GB-0022 v03 09/29/2020
9.2.8 Object 0x1011: Reset Backup Parameters
This object supports the restoring of the default values of all writable parameters.
Subindex 0: Number of entries
Contains the largest array subindex
Subindex 1: Factory settings for all parameters
Configures all parameters, for which factory settings are
available, with their factory settings. This only occurs if the
value
0x64616F6C
is written. This is the numeric value resulting from the "load"
character string ('l' : 0x6C, 'o': 0x6F, 'a' : 0x61, 'd': 0x64).
Subindex 3: Factory settings for application parameters (0x6xxx-objects)
Subindex 4: Factory settings for manufacturer-specific parameters (0x2xxx-objects)