EasyManuals Logo

Trio Motion Coordinator MC206 User Manual

Default Icon
566 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #298 background imageLoading...
Page #298 background image
8-108Trio BASIC Commands
System Parameters and Commands
Trio Motion Technology
NETSTAT
Type:
System Parameter
Description:
This parameter stores the network error status since the parameter was last cleared
by writing to it. The error types reported are:
NEW
Type:
System Command
Description
Deletes all the program lines in the controller memory. It also may be used to
delete the current
TABLE
entries.
Note:
NIO
Type:
System Parameter (Read Only)
Description:
This parameter returns the number of inputs/outputs fitted to the system, or con-
nected on the IO expansion CAN bus.
Bit Set Error Type Value
0TX Timeout 1
1 TX Buffer Error 2
2
RX CRC Error 4
3RX Frame Error 8
NEW
Deletes the currently selected program
NEW progname
Deletes a particular program
NEW ALL
Deletes all programs in memory
NEW "TABLE"
Delete TABLE (In this case ONLY the program name “TABLE
must be in quotes)