2-28 Hardware Overview
Motion Coordinator MC206
Trio Motion Technology
I/O Connector 3
Amplifier Enable (Watchdog) Relay Output
An internal relay contact is used to enable external amplifiers when the control-
ler has powered up correctly and the system and application software is ready.
The amplifier enable is a single pole relay with a set of normally open contacts.
The enable relay contact will be open circuit if there is no power on the control-
ler OR a following error exists on a servo axis OR the user program sets it open
with the WDOG=OFF command.
The amplifier enable relay may, for example, be incorporated within a hold-up
circuit or chain that must be intact before a 3-phase power input is made live.
Amplifier Enable Output
Note:
ALL STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED WHEN THE
AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT
I/O Connector 3
WDOG / Ref. Enc. / Analog Outputs
Reference Encoder (Axis 4) 0v
Reference Encoder (Axis 4) A
Reference Encoder (Axis 4) /A
Reference Encoder (Axis 4)/B
Reference Encoder (Axis 4) Z
Reference Encoder (Axis 4) /Z
Analog Outputs 0v (Axes 0-3)
Analog Output - Axis 0
Analog Output - Axis 1
Analog Output - Axis 2
Analog Output - Axis 3
Reference Encoder (Axis 4) B
Amplifier Enable Relay
(Watchdog)
0v
24v
Amplifier
Enable 1
Amplifier
Enable 2
V+
V -
0v
Enable
VIN +
VIN -
SERVO
AMPLIFIER
To other axis enables
Trio Controller

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trio Motion Coordinator MC206 and is the answer not in the manual?

Trio Motion Coordinator MC206 Specifications

General IconGeneral
BrandTrio
ModelMotion Coordinator MC206
CategoryController
LanguageEnglish

Related product manuals