5.18.1.5 System Restored from Backup
Message
UBX-UPD-SOS
Description
System Restored from Backup
Firmware
Supported on:
u-blox 9 with protocol version 27
Type
Output
Comment
The message is sent from the device to notify the host the BBR has been restored from a
backup file in flash. The host should clear the backup file after receiving this message. If the
UBX-UPD-SOS message is polled, this message will be resent.
Header Class ID Length (Bytes) Payload Checksum
Message Structure
0xB5 0x62 0x09 0x14 8
see below
CK_A CK_B
Payload Contents:
Byte Offset Number
Format
Scaling Name Unit Description
0 U1 - cmd - Command (must be 3)
1 U1[3] - reserved1 - Reserved
4 U1 - response - 0: Unknown
1: Failed restoring from backup file
2: Restored from backup file
3: Not restored (no backup)
5 U1[3] - reserved2 - Reserved
UBX-18010854 - R04 Advance Information Page 188 of 259

Table of Contents

Other manuals for u-blox ZED-F9P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the u-blox ZED-F9P and is the answer not in the manual?

u-blox ZED-F9P Specifications

General IconGeneral
GNSSGPS, GLONASS, Galileo, BeiDou, QZSS, SBAS
Concurrent GNSS4
RTKYes
Velocity Accuracy0.05 m/s
Time Pulse Accuracy30 ns
Operating Temperature-40°C to +85°C
Supply Voltage2.7 V to 3.6 V
Channels184
Frequency BandsL1, L2
Dimensions22 mm x 17 mm x 2.4 mm
InterfacesUART, SPI, I2C