EasyManua.ls Logo

u-blox ZED-F9P - CFG-I2 COUTPROT: Output Protocol Configuration of the I2 C Interface; CFG-INFMSG: Inf Message Configuration

u-blox ZED-F9P
267 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
u-blox ZED-F9P Interface Description - Manual
Advance Information
CFG-I2CINPROT-* Configuration Items
Configuration Item Key ID Type Scale Unit Description
CFG-I2CINPROT-UBX 0x10710001 L - - Flag to indicate if UBX should be an
input protocol on I2C
CFG-I2CINPROT-NMEA 0x10710002 L - - Flag to indicate if NMEA should be an
input protocol on I2C
CFG-I2CINPROT-RTCM3X 0x10710004 L - - Flag to indicate if RTCM3X should be
an input protocol on I2C
6.7.5 CFG-I2COUTPROT: Output Protocol Configuration of the I2C Interface
Output protocol enable flags of the I2C interface.
CFG-I2COUTPROT-* Configuration Items
Configuration Item Key ID Type Scale Unit Description
CFG-I2COUTPROT-UBX 0x10720001 L - - Flag to indicate if UBX should be an
output protocol on I2C
CFG-I2COUTPROT-NMEA 0x10720002 L - - Flag to indicate if NMEA should be an
output protocol on I2C
CFG-I2COUTPROT-RTCM3X 0x10720004 L - - Flag to indicate if RTCM3X should be
an output protocol on I2C
6.7.6 CFG-INFMSG: Inf Message Configuration
Information message configuration for the NMEA and UBX protocols.
CFG-INFMSG-* Configuration Items
Configuration Item Key ID Type Scale Unit Description
CFG-INFMSG-UBX_I2C 0x20920001 X1 - - Information message enable flags for
the UBX protocol on the I2C interface
See Constants for CFG-INFMSG-UBX_I2C below for a list of possible constants for this item.
CFG-INFMSG-UBX_UART1 0x20920002 X1 - - Information message enable flags for
the UBX protocol on the UART1
interface
See Constants for CFG-INFMSG-UBX_UART1 below for a list of possible constants for this item.
CFG-INFMSG-UBX_UART2 0x20920003 X1 - - Information message enable flags for
the UBX protocol on the UART2
interface
See Constants for CFG-INFMSG-UBX_UART2 below for a list of possible constants for this item.
CFG-INFMSG-UBX_USB 0x20920004 X1 - - Information message enable flags for
the UBX protocol on the USB interface
See Constants for CFG-INFMSG-UBX_USB below for a list of possible constants for this item.
CFG-INFMSG-UBX_SPI 0x20920005 X1 - - Information message enable flags for
the UBX protocol on the SPI interface
See Constants for CFG-INFMSG-UBX_SPI below for a list of possible constants for this item.
CFG-INFMSG-NMEA_I2C 0x20920006 X1 - - Information message enable flags for
the NMEA protocol on the I2C
interface
See Constants for CFG-INFMSG-NMEA_I2C below for a list of possible constants for this item.
UBX-18010854 - R04 Advance Information Page 194 of 259