28
configuration is 125VDC or 120VAC. The input can also be factory configured to accept 250V or
48V DC input voltage.
Remote Power Off
This optional connection is used to control power to the M9000 module from a remote location.
Applying a voltage between 5VDC and 200VDC to this input disables the DC-to-DC converter
output which powers down the Station-Master computer.
Output Power
This connection is used to supply power to the Station-Master computer.
ETH0
This connection provides access to the DME system local network. This allows communication with
the M9000 or Power Supply modules.
ETH1, ETH2
These connections are used to connect the Power Supply module to the DME system local
network. This is a required connection.
3A SB Fuse
This fuse protects the board from excessive input current.
Alarm 1 - 8
These connections provide status outputs for the DME system:
o Alarm 1:
This output indicates the status of the ON LINE indicator.
o Alarm 2:
This output indicates the status of the TRIGGER indicator.
o Alarm 3:
This output indicates the status of the CLOCK SYNC indicator.
o Alarm 4:
This output indicates the status of the COMMUNICATION indicator.
o Alarm 5:
This output indicates the status of the POWER indicator.
o Alarm 6:
This output indicates the status of the DISK indicator.
o Alarm 7:
This output indicates the status of the TEMPERATURE indicator.
o Alarm 8:
This output is reserved for future use.