HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-67© VEMAG 2013
Number Message Cause Remedy
561 Machine parameters are
missing
Serious problem when loading
machine parameters.
Software update or reinstallation.
Make a note of the error number
and inform the VEMAG Customer
Service team.
563 Machine parameters set
to default
Loaded machine parameter was
outside valid range - set to default.
Check whether the machine is
running correctly. Note the fault
number and contact VEMAG Serv-
ice. Production may be possible.
571 Machine parameters are
missing
Serious problem when loading
machine parameters.
Software update or reinstallation.
Make a note of the error number
and inform the VEMAG Customer
Service team.
573 Program parameter un-
known
Following a software update, there
are often new parameters which
require the SRAM to be reorgan-
ized. This is done automatically
and is conrmed by a second
message 573 with a blue symbol.
-
574 Program memory may be
defective
A rare fault has occurred in the
program memory.
Check program parameters.
If possible/necessary, re-load the
recipes or enter the data manually.
Note the fault number and contact
VEMAG Service. Production may
be possible.
575 Program parameter set to
default
Loaded machine parameter was
outside valid range - set to default.
Check all the parameters of the
current program and correct them
if necessary.
600 Remote contact activated! The A-C remote control signal
is active in KNEE modes.
Switch to REMOTE mode or re-
move the remote control connector.
601 Jumper A-D is missing
in remote plug!
An A-D jumper is expected
in the remote control connector
in REMOTE modes.
Switch to KNEE mode or plug in
the remote control connector.
602 Portion end not reached! Portion was interrupted, for exam-
ple in Remote-Stop mode.
-
603 Remote control blocked
by casing pusher
The casing pusher option is pre-
venting selection of remote mode.
If desired, deactivate the casing
pusher option and switch to RE-
MOTE mode.
604 Casing pusher blocked
by remote control
REMOTE mode is preventing se-
lection of the casing pusher option.
If desired, switch to KNEE mode
and activate the casing pusher
option.
605 Metal detection Machine stopped because metal
detected.
Further action depends on the metal
detector used and on mode. Con-
tact VEMAG Service if necessary.
606 Target position not
reached
The main drive required more than
double the calculated time.
This may be an indication that
product is too cold or too dense.