Number Message Cause Remedy
422 ********** too light Scale 877 The sample is min. 20 g
lighter than the set weight.
To have the sample weight accepted,
place the sample on the scale again.
423 too heavy ********** Scale 877 The sample is min. 20 g
heavier than the set weight.
To have the sample weight accepted,
place the sample on the scale again.
424 ***** +-12.5% ***** Scale 877 The variation in sample
weight exceeds 12.5 % of the set
weight. The sample is not accepted.
-
425 Check feed element or
number of samples put on
scale
Scale 877 The sample weight
undershoots set weight by 20 %
or overshoots it by 200 %.
Check setting on PC. Check feed
element.
426 Release scale Scale 877 Operator is requested
to take weight off the scale.
-
450 Hopper empty? Vacuum hopper 149: the product
height in the hopper is less than
the dened limit.
Fill the hopper again or change the
hopper mode from „Automatic“ to
„Off“,“Vacuum“, or „Cleaning“ to
deactivate hopper monitoring.
501 Hopper The hopper is open. Close the hopper.
502 External safety switch The external safety switch or
circuit is open (F6-S4).
Close the external safety switch or
circuit. Check external socket X29.
503 Filling horn holder The lling horn holder or the link-
ing gear is missing.
Insert the lling horn holder or the
linking gear or insert again.
504 Please press the start
button
In order to restart a machine
equipped with an external safety
switch after a safety-related inci-
dent, approval is required again.
Press the start button.
505 Feed system The feed system is open. Close the feed system or close
it again.
507 Safety cover open A safety cover is open. Close the safety cover or close
it again.
541 Recipes loaded Programs/recipes have been loaded
from the USB stick into the machine.
-
542 Recipes saved The programs/recipes used have
been saved on a USB stick.
-
555 The operating mode is not
correct for the attachment
The detected attachment is not
correct for the selected program/
for the selected operating mode.
Select the correct program/the
correct operating mode.
556 Attachment 1 not ready The connected attachment is not
ready for use.
Check the attachment for open
safety cover, etc.