Videojet DataFlex 6530 Service Manual - Rev AA 8-7
Troubleshooting
E1217 Invalid Job File
- Undefined
Format
Identifier
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file uses a
Public Format ID which is not currently defined.
Press the Clear button, to clear this fault message.
E1218 Invalid Job File
- Data too long
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file
contains too many data characters for the selected
dimensions.
Press the Clear button, to clear this fault message.
E1219 Invalid Job File
- Invalid
Barcode Size
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file has
invalid dimensions.
Press the Clear button to clear this fault message.
E1220 Invalid Job File
- Invalid
Barcode ECC
Type
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file has
an unsupported ECC type. Only ECC 200 is currently
supported.
Press the Clear button to clear this fault message.
E1221 Invalid Job File
- Barcode uses
unsupported
coding
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file uses a
form of data compression not currently supported by
CLARiTY.
Press the Clear button to clear this fault message.
E1222 Invalid Job File
- Barcode
encoding failed
The Job file is invalid and needs to be corrected using
CLARiSOFT. A Data Matrix Barcode field in the Job file failed
to encode into a valid image.
Press the Clear button to clear this fault message.
E1223 Invalid Job File
- Invalid Date
Reference
The Job file contains a date reference not supported by this
printer. Use CLARiSOFT to set the 'Reference Date' for all
Calculated Dates to 'Current Date'. Then, download the
corrected file to the printer.
Press the Clear button, to clear this fault message.
E1224 Invalid Job File
- Invalid Date
Rounding
The Job file contains a date with a rounding calculation that is
not supported by this printer. Use CLARiSOFT to remove the
Rounding for all Calculated Dates. Then, download the
corrected file to the printer.
Press the Clear button, to clear this fault message.
E1225 Invalid Job File
- Invalid Coun-
ter
The Job file contains a counter that is not supported by this
printer. Use CLARiSOFT to remove all counters from the job.
Then, download the corrected file to the printer.
Press the Clear button, to clear this fault message.
Error
Reference
Name Remedial Action
Table 8-1: Faults and Warnings (Continued)

Table of Contents