8-10 Videojet DataFlex 6530 Service Manual - Rev AA
Troubleshooting
E1241 CLARiTY Data
File Failed
There is a problem with the installed CLARiTY Data file.
Please select a new Job or install a new CLARiTY Data file to
resume printing.
Press the Clear button, to clear this fault message.
E1242 Invalid Job File
- Barcode data
too long
The Job file is invalid and needs to be corrected using
CLARiSOFT. A QR Barcode field in the job file contains too
many data characters for the selected dimensions.
Press the Clear button, to clear this fault message.
E1243 Invalid Job File
- Avoidance
Date
The Job file contains a calculated date that is an avoidance
date. Use CLARiSOFT to check and correct the calculated
dates in the job. Then, download the corrected file to the
printer.
Select a valid Job and then press Clear button, to clear this
fault message.
E1300 Slave Printer
Absent
This printer is configured as the Master to a group of Slave
printers, Slave printer %1 is assigned to this Master, but it is
not responding. Please check the wiring connections between
this Master printer and Slave %1 printer, then power both this
Master and Slave %1 off then on, to try and clear this fault. If
the problem persists, Contact your maintenance engineer.
If you want to continue production without Slave %1, please
go to Tools > Setup > Printheads > Slave%1 and un-assign
Slave%1.
E1301 Master Printer
Absent
This printer is configured as a Slave printer to a Master
printer in a group of printers, The Master printer is not
responding to this Slave printer. Please check the wiring
between this printer and the Master printer, then power both
printers off then on, to try and clear this fault. If the problem
persists, contact your maintenance engineer.
E1302 Slave Job Select
Failed
Slave Printer %1 failed to select the current job.
Please check the wiring between this printer and the Master
printer, then power both printers off then on, to try and clear
this fault. If the problem persists, Contact your maintenance
engineer.
E1303 Slave Database
Full
Slave Printer %1 has failed to receive a file because it has run
of space. This usually occurs when a slave printer has a
smaller database capacity than the master, if this is the case
then it is recommended that the slave database is upgraded.
To ensure trouble free operation, delete some jobs out of the
master printer database and then repower the master printer.
This will cause the master and slave databases to be
resychronised.
Press the Clear button, to clear this fault message.
Error
Reference
Name Remedial Action
Table 8-1: Faults and Warnings (Continued)