Videojet DataFlex 6530 Service Manual - Rev AA 8-11
Troubleshooting
E1304 Slave Software
Version
Slave Printer %1 has failed to communicate with the Master
Printer because its software is too old. Please perform a
CLARiTY Update to the latest revision of software to resolve
this problem.
E1305 Slave Job
Update Failed
Slave Printer %1 failed to update the printing data for the
current job. Please check the wiring between this printer and
the Master printer, then power both printers off then on, to try
and clear this fault. If the problem persists, contact your
maintenance engineer.
E1500 Log File
Corruption
Corruption has been detected in the log file. Please navigate
to Tools > Diagnostics > Control > Log Files for more details.
Press the Clear button, to clear this warning message.
E1501 Log File Space
Critical
The available space for logging has reached a
critical level. Please archive the log file or delete unnecessary
files from the Job database to free up some space. This fault
message will clear automatically when the free space is
increased.
E1502 Log File Space
Limited
The available space for logging becoming limited. Please
archive the log file or delete unnecessary files from the Job
database to free up some space.
Press the Clear button, to clear this warning message
E1503 Logging Space
Exhausted
The available space for logging is exhausted. Please archive
the log file to free up some space.
Press the Clear button, to clear this fault message
E1504 Log File Save
Failed
Failed to save log file information. Some log file information
has been lost.
Press the Clear button, to clear this fault message.
E1505 Logging Job
Events
Disabled
Logging of Job events has been disabled. This is because Job
selections and Job updates are happening too frequently. The
printer can only log Job events once every 10 seconds.
Logging of Job events can be re-enabled via the
IncludeJobEvents parameter in CLARiTY Configuration
manager if the frequency of Job events is reduced.
Press the Clear button, to clear this warning message.
E3200 iAssure Setup
Required
Please press the Start Setup button to setup the iAssure
sensor.
E3201 Motor
Characteriza-
tion Required
The ribbon motors have not been characterized. To
characterize the ribbon motors:
- Install the ribbon cassette with no ribbon fitted to the ribbon
mandrels.
- Press the Characterize Ribbon Motors button.
Once the characterization completes, this fault will clear
automatically.
Error
Reference
Name Remedial Action
Table 8-1: Faults and Warnings (Continued)