February 2013
4-288
ColorQube® 9303 Family
REP 81.1, REP 81.2
Repairs/Adjustments
6. Remove tray 1 or tray 2 feed assembly. Figure 3.
Figure 3 Removal
Replacement
1. Replacement is the reverse of the removal procedure.
2. To install the lower left door assembly. Install the three screws, close the door and align
the hinge with the marking on the frame. Secure the screws and check that the door
opens and closes correctly, Figure 1.
3. If new feed rolls are installed, reset the tray 1 or tray 2 feed count to zero. Refer to dC135
CRU / HFSI Status.
REP 81.2 Tray 3 Paper Feed Assembly
Parts List on PL 81.30
Removal
WARNING
Switch off the electricity to the machine. Refer to GP 14. Disconnect the power cord
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1. Pull out tray 3.
2. Remove tray 1 and the horizontal transport, REP 82.3.
3. Remove the paper feed assembly, Figure 1.
Figure 1 Tray 3 feed assembly
Tray 1 feed assembly
Tray 2 feed
assembly
2
Remove the screws then slide
the feeder out as required.
Remove the screws then
the cover
1
Remove the
screw.
2
Push Left, to reveal the harness.