February 2013
6-202
ColorQube® 9303 Family
dC131
General Procedures/Information
606-769 IMETTMInterrupt-
StormFC
Fault Counter 92-548-00: TTM
Interrupt Storm
Number of faults
Range = 0 to 255
0
606-770 IMEPFPInterrupt-
StormFC
Fault Counter 92-549-00: PFP
Interrupt Storm
Number of faults
Range = 0 to 255
0
606-771 IMECISInterrupt-
StormFC
Fault Counter 92-551-00: CIS
Interrupt Storm
Number of faults
Range = 0 to 255
0
606-772 IMESBCInterrupt-
StormFC
Fault Counter 92-552-00: SBC
Interrupt Storm
Number of faults
Range = 0 to 255
0
606-773 IMECalScanDe-
tectedFPExcep-
tionFC
Fault Counter 89-567-00: Cali-
bration scan detected floating
point exception
Number of faults
Range = 0 to 255
0
606-774 PQM Insufficient
Ink
Fault Counter 91-824-00: PQM
Insufficient Ink
Number of faults
Range = 0 to 255
0
606-775 PQM Insufficient
Jets
Fault Counter 91-826-00: PQM
Insufficient Jets
Number of faults
Range = 0 to 255
0
606-776 PQM Insufficient
Jets
Fault Counter 91-826-00: PQM
Insufficient Jets
Number of faults
Range = 0 to 255
0
606-777 PQM Align
Needed
Fault Counter 91-827-00: PQM
Align Needed
Number of faults
Range = 0 to 255
0
606-778 PQM Y Dot Posi-
tion Needed
Fault Counter 91-828-00: PQM
Y Dot Position Needed
Number of faults
Range = 0 to 255
0
606-779 PQM Drum
Runout Needed
Fault Counter 91-829-00: PQM
Drum Runout Needed
Number of faults
Range = 0 to 255
0
606-780 PQM Uniformity
Needed
Fault Counter 91-830-00: PQM
Uniformity Needed
Number of faults
Range = 0 to 255
0
606-781 PQM Uniformity
Reset Needed
Fault Counter 91-831-00: PQM
Uniformity Reset Needed
Number of faults
Range = 0 to 255
0
606-782 PQM Empty
Waste Tray
Fault Counter 91-832-00: PQM
Empty Waste Tray
Number of faults
Range = 0 to 255
0
606-783 PQM Cleaning
Pages Needed
Fault Counter 91-833-00: PQM
Cleaning Pages Needed
Number of faults
Range = 0 to 255
0
606-784 PQM Tool Not
Usable
Fault Counter 91-834-00: PQM
Tool Not Usable
Number of faults
Range = 0 to 255
0
606-785 PQM Tool Manu-
ally Disabled
Fault Counter 91-835-00: PQM
Tool Manually Disabled
Number of faults
Range = 0 to 255
0
606-786 PQM: System
Busy
Fault Counter 91-836-00: PQM-
00: System Busy
Number of faults
Range = 0 to 255
0
606-787 FS23.201 Table
Version
Default is the version number of
the Excel table used to create
the NVM
Range = 0 to
65535
1249
606-788 DrumFanShrou-
dUsage
Drum Fan Shroud - Number of
impressions
Range = 0 to
4294967295
0
606-789 TransfixStripperU-
sage
Transfix Stripper - Number of
impressions
Range = 0 to
4294967295
0
Table 15 CCS NVM ID 606-270 to 606-900
NVM ID NVM Name NVM Description Settings Default
606-790 UpperJLBaffle-
Usage
Upper JL Baffle - Number of
impressions
Range = 0 to
4294967295
0
606-791 DrumFanShroud-
Cleanings
Drum Fan Shroud - Number of
cleanings
Range = 1 to
65535
1
606-792 TransfixStripper-
Cleanings
Transfix Stripper - Number of
cleanings
Range = 1 to
65535
1
606-793 UpperJLBaffle-
Cleanings
Upper JL Baffle - Number of
cleanings
Range = 1 to
65535
1
606-794 DrumFanShroud-
MaintThreshold
Drum Fan Shroud - Mainte-
nance threshold
Range = 1 to
4294967295
500000
606-795 TransfixStripper-
MaintThreshold
Transfix Stripper - Maintenance
threshold
Range = 1 to
4294967295
125000
606-796 UpperJLBaffle-
MaintThreshold
Upper JL Baffle - Maintenance
threshold
Range = 1 to
4294967295
400000
606-797 Not displayed Drum Fan Shroud Last Cleaned
Date
Range = 1 to
4294967295
0
606-798 Not displayed Transfix Stripper Last Cleaned
Date
Range = 1 to
4294967295
0
606-799 Not displayed Upper JL Baffle Last Cleaned
Date
Range = 1 to
4294967295
0
606-801 PapPusher-
SwitchFC
Fault Counter 12-444: Paper
Pusher Switch Fault
Number of faults
Range = 0 to 255
0
606-802 BlackInkLoader-
JammedFC
Fault Counter 93-501-00: Black
Ink loader Jammed
Number of faults
Range = 0 to 255
0
606-803 MagentaInkLoad-
erJammedFC
Fault Counter 93-506-00:
Magenta Ink loader Jammed
Number of faults
Range = 0 to 255
0
606-804 CyanInkLoader-
JammedFC
Fault Counter 93-511-00: Cyan
Ink loader Jammed
Number of faults
Range = 0 to 255
0
606-805 YellowInkLoader-
JammedFC
Fault Counter 93-516-00: Yel-
low Ink loader Jammed
Number of faults
Range = 0 to 255
0
606-806 Default Staple
Position
Default Staple position (HVF
only)(Staple positioning: trades
best position verses best pro
-
ductivity) Default set to best
productivity to give best BLI test
result. Customer can then
select which mode best suites
them.
Range = 1 to 2 2
606-807 Head1NvramJetM
askReadErrorFC
Fault Counter 91-842-00: Head
#1 Nvram jet mask section read
or decode error
Number of faults
Range = 0 to 255
0
606-808 Head2NvramJetM
askReadErrorFC
Fault Counter 91-843-00: Head
#1 Nvram jet mask section read
or decode error
Number of faults
Range = 0 to 255
0
Table 15 CCS NVM ID 606-270 to 606-900