February 2013
2-24
ColorQube® 9303 Family
01D
Status Indicator RAPs
– Cleaning unit home sensor, PL 94.10 Item 17
– Post transfix sensor, PL 10.10 Item 6
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new drum driver PWB, PL 1.15 Item 4, or one of the components in
the list above
Media Path Driver PWB
• To view the +5V distribution from the power supply unit, refer to WD 1.5
• For +5V faults on the media path driver PWB, refer to:
– WD 8.1
– WD 8.2
– WD 8.3
– WD 8.4
– WD 8.5
– WD 8.6
• The +5V LED on this PWB is shown in WD 8.5
• The components that follow are driven from the media path driver PWB:
– Registration/Pre-heat interface PWB, PL 88.10 Item 10 see below for components
driven by this PWB
– Vertical transport sensor, PL 82.10 Item 7
– Confirm sensor, PL 82.10 Item 7
– Vertical transport motor encoder, part of the vertical transport motor, PL 82.10 Item
12
– 3 Tray module, PL 73.16 and components, see below for components driven by this
PWB
– Bypass empty sensor, PL 74.10 Item 18
– Bypass feed sensor, PL 74.10 Item 19
– Bypass nudger home sensor, PL 74.10 Item 18
– Tray 5 control PWB, PL 75.68 Item 8 see below for components driven by this PWB
–OCT PL 12.00 Item 1
– LCSS PWB, PL 12.75 Item 1, see below for components driven by this PWB
– HVF PWB PL 12.140 Item 2, see below for components driven by this PWB
– Duplex start sensor PL 10.15 Item 3
– Exit sensor PL 10.15 Item 3
– Duplex sensor PL 82.15 Item 3
– Horizontal transport motor encoder, part of the horizontal transport motor, PL 82.15
Item 9
– Duplex end sensor PL 82.15 Item 3
• Repair the wiring as necessary, REP 1.1
• If necessary, install a new media path driver PWB, PL 1.15 Item 5, or one of the compo-
nents in the list above.
Power Distribution PWB
• To view the +5V distribution from the power supply unit, refer to WD 1.5.
• For +5V faults on the power distribution PWB, refer to:
– WD 1.6
– WD 1.7
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new power distribution PWB, PL 3.11 Item 1.
3 Tray Module PWB
• To view the +5V distribution from the media path driver PWB, refer to WD 8.2.
• For +5V faults on the 3 tray module PWB, refer to:
– WD 7.3.
– WD 7.4.
– WD 7.5
• The +5V LED on this PWB is shown in WD 7.3.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new 3 tray module PWB, PL 73.16 Item 4.
Registration / Pre-heat Interface PWB
• To view the +5V distribution from the drum driver PWB, refer to WD 9.2.
• To view +5V distribution from the media path driver PWB, refer to WD 8.1.
• For +5V faults on the registration/preheat interface PWB, refer to WD 8.6.
• The components that follow are driven from +5V from the reg/preheat interface PWB:
– Reg/preheat home sensor, part of PL 88.10 Item 10.
– Pre transfix sensor Q89-006. PL 88.10 Item 12.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new Registration/Pre-heat interface PWB, PL 88.10 Item 10, or one
of the components in the list above.
Marking Unit Driver PWB
• To view the +5V distribution from the IME controller PWB, refer to WD 9.7
• For +5V faults on the marking unit driver PWB, refer to WD 9.10
• Repair the wiring as necessary, REP 1.1.
• If necessary install a new marking unit driver PWB, PL 92.10 Item 4
Tray 5 Control PWB
• To view the +5V distribution from the media path driver PWB, refer to WD 8.4.
• For +5V faults on the tray 5 control PWB, refer to:
– WD 7.1.
– WD 7.2.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new tray 5 control PWB, PL 75.68 Item 8.
Single Board Controller PWB
• To view the +5V distribution from the power distribution PWB, refer to WD 1.6.
• For +5V faults on the single board controller PWB, refer to:
– WD 3.1.
– WD 3.2.
• If necessary repair the wiring, REP 1.1.
• If necessary, install a new single board controller PWB, PL 3.11 Item 13.
Scanner PWB
• To view the +5V distribution from the power distribution PWB, refer to WD 1.7.
• For +5V faults on the scanner PWB, refer to:
– WD 6.1.
– WD 6.2.
– WD 6.3.
• Repair the wiring as necessary, REP 1.1.
• If necessary, install a new scanner PWB, PL 62.16 Item 8.