Image Quality
3-14 04/07 Phaser 3200MFP / Workcentre PE220
IQ 12 Ghost (4)
Description
Ghost occurs at 47.5mm(or 63.9mm) intervals.
Check and Cause Solution
1. The temperature of the fuser is
too high because the thermistor is
contaminated.
CAUTION
Take care not to bend or break the
thermistor.
1. Clean the heat roll, pressure roll
and thermistor:
- PL 7.0
(Workcentre PE220)
- PL 7.1
(Phaser 3200)
Check and install a new fuser
assembly if necessary:
- PL 1.0
(Workcentre PE220)
- PL 1.1
(Phaser 3200)