ELEC
Electrical systems
+
8-27
62Y3A11
NOTE:
After starting the engine, disconnect the out-
put lead (red lead) of the Rectifier Regulator
when measuring the output peak voltage.
Rectifier Regulator output peak voltage:
Red (R) Black (B)
r/min
Unloaded
1,500 3,500
DC V 18.9 19.5