8.3 Alarm Message List
8-6
0030 ROM ERROR
The system program file is damaged.
If the error occurs again, contact your
Yaskawa representative.
1 • The NCP01 system program is
damaged.
10 • The system program of optional
board #1 is damaged.
20 • The system program of optional
board #2 is damaged.
50 • The system program of servo
board #1 is damaged.
51 • The system program of servo
board #2 is damaged.
52 • The system program of servo
board #3 is damaged.
53 • The system program of servo
board #4 is damaged.
0060
COMMUNICA-
TION ERROR
(I/O MODULE)
1 to
15
An error was detected in communi-
cations with an I/O module board
when the control power turned ON.
• Turn the power OFF then back ON.
• Check the connections of communications
cable, terminator terminal, and the station
number settings.
If the error occurs again, contact your
Yaskawa representative.
0100
COMMUNICA-
TION ERROR
(AXA#1)
1 An error occurred in communica-
tions with the servo board #1.
• The error was detected during the
check of the CERF communica-
tion watchdog data.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
2 An error occurred in communica-
tions with the servo board #1.
• The error was detected during the
check of the number of the CERF
communications.
0101
COMMUNICA-
TION ERROR
(AXA#2)
1 An error occurred in communica-
tions with the servo board #2.
• The error was detected during the
check of the CERF communica-
tion watchdog data.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
2 An error occurred in communica-
tions with the servo board #2.
• The error was detected during the
check of the number of the CERF
communications.
0102
COMMUNICA-
TION ERROR
(AXA#3)
1 An error occurred in communica-
tions with the servo board #3.
• The error was detected during the
check of the CERF communica-
tion watchdog data.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
2 An error occurred in communica-
tions with the servo board #3.
• The error was detected during the
check of the number of the CERF
communications.
0103
COMMUNICA-
TION ERROR
(AXA#4)
1 An error occurred in communica-
tions with the servo board #4.
• The error was detected during the
check of the CERF communica-
tion watchdog data.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy