8.3 Alarm Message List
8-7
0103
COMMUNICA-
TION ERROR
(AXA#4)
2 An error occurred in communica-
tions with the servo board #4.
• The error was detected during the
check of the number of the CERF
communications.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
0200
MEMORY
ERROR
(PARAMETER
FILE)
The parameter file is damaged.
• Initialize the corresponding parameter file in
the maintenance mode.
If the error occurs again, contact your
Yaskawa representative.
0 RC parameter
1RO parameter
2 SV parameter
3 SVM parameter
4SC parameter
5SD parameter
6 CIO parameter
7FD parameter
8 AP parameter
9RS parameter
10 SE parameter
11 SVC parameter
12 AMC parameter
13 SVP parameter
14 MF parameter
15 SVS parameter
0210 MEMORY
ERROR
(SYSTEM CON-
FIG-DATA)
0 The system configuration informa-
tion data are damaged.
• Initialize the system.
If the error occurs again, contact your
Yaskawa representative.
0220
MEMORY
ERROR
(JOB MNG DATA)
0 The management data of job files
are damaged.
• Initialize the job files in the maintenance
mode.
If the error occurs again, contact your
Yaskawa representative.
1 The job files are damaged.
2 The management data of position
data files are damaged.
3 The memory play file is damaged. • Initialize the memory play file.
If the error occurs again, contact your
Yaskawa representative.
0230 MEMORY
ERROR
(LADDER PRG
FILE)
0 The concurrent I/O ladder program
is damaged.
• Initialize the concurrent I/O ladder program.
If the error occurs again, contact your
Yaskawa representative.
0240 MEMORRY
ERROR
(DEVICENET
ALLOC FL)
0 The DeviceNet allocation file1 is
damaged.
• Use the IO module setting screen in the
maintenance mode to initialize the
DeviceNet allocation file.
If the error occurs again, contact your
Yaskawa representative.
1 The DeviceNet allocation file2 is
damaged.
0270 MEMORY
ERROR
(CF BACKUP
FILE)
--- The system software version is
inconsistent with the version when
the internal storage data is set or
the CompactFlash on the NCP01
board is damaged.
• Perform "DATA REBUILD" in the mainte-
nance mode.
• If the error occurs again after execution of
"DATA REBUILD," replace the Compact-
Flash on the NCP01 board.
If the error occurs again, contact your
Yaskawa representative.
0290 MEMORY
ERROR
(NETWORK
SETUP)
--- The network setting file is dam-
aged.
• Specify network settings again in mainte-
nance mode.
If the error occurs again, contact your
Yaskawa representative.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy