8.3 Alarm Message List
8-9
0370
VERIFY ERROR
(SPOT POWER
SOURCE I/F)
0 The designation in the parameter is
different from the connected weld-
ing timer.
Set a correct value for the welding timer des-
ignation.
0390
VERIFY ERROR
(SEGMENT
CLOCK)
1 The segment clock value which is
out of allowable range is set.
• Set a correct value for the segment clock.
If the error occurs again, contact your
Yaskawa representative.
2 The set value of segment clock is
insufficient for communication with
the servo board. Communication
cannot be performed with the servo
board
• Set a correct value, which is larger than the
current value, for the segment clock.
If the error occurs again, contact your
Yaskawa representative.
0400
PARAMETER
TRANSMISSION
ERROR
50 to
53
An error occurred during the
parameter/file transfer to the servo
board.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
0410
MODE CHANGE
ERROR
An error occurred during startup
sequence processing with the
servo CPU, and the system did not
startup normally.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
0420
DEVICENET
ALLOC FL
TRANSMIT ERR
0 The DeviceNet allocation file1
could not be transmitted to the
specified station.
• Verify the connection state of the DeviceNet
board specified by the DeviceNet alloca-
tion file.
• Use the IO module setting screen in the
maintenance mode to initialize the
DeviceNet allocation file.
If the error occurs again, contact your
Yaskawa representative.
1 The DeviceNet allocation file2
could not be transmitted to the
specified station.
0500
SEGMENT
PROC NOT
READY
--- Motion command processing was
not completed within the specified
time.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
0510
SOFTWARE
VERSION
UNMATCH
--- The combination of the main sys-
tem program and the servo system
program is incorrect.
Correct the combination.
0520
AXIS LIMIT
OVER
0 More axes than the set value are
used.
• Set the control group in the maintenance
mode with the connectable number of axes.
If the error occurs again, contact your
Yaskawa representative.
0600
MEDAR STATUS
ERROR
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0601
MEDAR DIAG-
NOSIS ERROR
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0602
MEDAR VER-
SION ERROR
-
-- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0603
MEDAR REVI-
SION ERROR
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0604
MEDAR MODE
CHANGE
ERROR
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0605
MEDAR SCHED-
ULE TRANSMIT
ERROR
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0606
MEDAR
ERROR1
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0607
MEDAR
ERROR2
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
0608
MEDAR
WELDER TYPE
MISMATCH
--- Refer to the instruction manual for
the MEDAR function.
Refer to the instruction manual for the
MEDAR function.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy

Table of Contents

Other manuals for YASKAWA NX100