8.3 Alarm Message List
8-12
0810
TOYOPUC
ALLOC DEF
ERROR
23 An error was found in the specified
number of registers which are used
by the system data.
Verify and modify the allocation configuration
data for the TOYOPUC.
30 In the input side setting of allocation
configuration data, the specified R-
register start No. for the TOYOPUC
exceeds the R-register limit.
31 In the input side setting of allocation
configuration data, the set number
to use the input side R-register of
the TOYOPUC exceeds the R-reg-
ister limit.
32 In the input side setting of allocation
configuration data, the set number
to use the M-register of concurrent
I/O exceeds the M-register limit.
34 An error was found in the specified
number of registers which are used
by the system data "standard time
setting data" of allocation configura-
tion.
41 In the output side setting of alloca-
tion configuration data, some of the
TOYOPUC’s R-registers are speci-
fied redundantly.
42 In the output side setting of alloca-
tion configuration data, some of the
M-registers of concurrent I/O are
specified redundantly.
44 In the input side setting of allocation
configuration data, some of the
TOYOPUC’s R-registers are speci-
fied redundantly.
45 In the input side setting of allocation
configuration data, some of the M-
registers of concurrent I/O are
specified redundantly.
0900
WATCHDOG
TIMER ERROR
(NIF BOARD)
--- A system operation error occurred. • Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
0910
CPU ERROR
(NCP01)
Vec-
tor
No.
An error was detected in the CPU.
Replace the NCP01 board.
0911
CPU ERROR
(NCP02#1)
100 An error was detected in the CPU
of the optional board#1.
Replace the corresponding optional board.
0912
CPU ERROR
(NCP02#2)
100 An error was detected in the CPU
of the optional board#2.
Replace the corresponding optional board.
0920
BUS ERROR
(NCP01)
1 The JL chip does not operate nor-
mally.
Replace the NCP01 board.
0930
CPU HANG UP
ERROR (NCP01)
0 Power lost is detected • Verify the state of primary power supply.
• Verify the CPS power supply.
If the error occurs again, contact your
Yaskawa representative.
0950
CPU ERROR
(AXA#1)
100 An error was detected in the CPU
of servo board #1.
Replace the corresponding servo board.
0951
CPU ERROR
(AXA#2)
100 An error was detected in the CPU
of servo board #2.
Replace the corresponding servo board.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy

Table of Contents

Other manuals for YASKAWA NX100

Related product manuals