8.3 Alarm Message List
8-70
4401
SEQUENCE
TASK CONTROL
ERROR
An error occurred in job execution process.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
26 • Intermediate code is not defined.
29 • Instruction prereading processing
has not been completed normally.
30 • An error occurred in job data
change.
31 • The specified sequence number
at job execution start is incorrect.
32 • The added area for interruption
command is incorrect.
33 • System number (MSS) for inter-
ruption command is incorrect.
38 • An error occurred at start of twin
synchronous operation.
39 • An error occurred when SYNC
specification was reset.
41 • An error occurred in occupation
control group setting in MOTION.
45 • An error occurred in path/trace
control.
47 • An error occurred when waiting for
a completion of main system task
(job) in SYNC specification.
48 • An attempt was made to execute
an instruction that could not be
executed at line sequence execu-
tion.
80 • An exceptional error occurred in
job execution process.
100 • Main processing command is
incorrect in prereading process-
ing.
101 • Subprocessing command is incor-
rect in prereading processing.
102 • Prereading processing has not
been completed at job execution.
103 • A_BANK conversion has not been
completed.
104 • System number (MSS) is incorrect
in prereading processing.
105 • An error occurred in instruction
prefetch queue operation in pre-
reading processing.
106 • An error occurred at IES switching
in prereading processing.
4402 UNDEFINED
COMMAND
(ARITH)
An undefined command was issued
to the path control section.
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy